10. Close the choke located underneath the air filter.
(Omit this step if the engine is already warm.)
11. First, all switches on the instrument panel should
be in the "OFF" position. Then, connect the multi-
pronged connector to the digital flow instrument
panel.
12. Turn the 4-way fluid control valve, located on the
control module, to the "OFF" position.
13. Put on all personal protective gear.
14. Add the calculated amount of pesticide to the
pesticide tank (REMEMBER, ULV/ULD
MACHINES USE ONLY CONCENTRATED
LIQUIDS).
15. To calibrate the machine, first set the flow rate on
the digital remote instrument panel. To readjust the
flow rate, remove the control module cover and
gently turn the adjustment knob on the blue pointer
located under the pump, to the left or right. The
pressure bypass toggle switch, located on the
machine control module, should be in the "ON"
position FOR THE CALIBRATION PROCEDURE
ONLY.
16. During spray operations, set the pressure bypass
toggle switch, located on the machine at the
control module, to the "OFF" position.